LISTA DE CODIGOS
C0000: Main Motor malfunction The Lock signal remains HIGH for a continuous 1-sec.
period while the Main Motor remains energized.
C0010: I/C Motor malfunction The Lock signal remains HIGH for a continuous 1-sec.
period while the I/C Motor remains energized.
C0045: Cooling Fan Motor malfunction
The Lock signal remains HIGH or LOW for a continuous
1-sec. period or more while the Cooling Fan Motor
remains energized.
C004C: Ozone Fan Motor malfunction
The Lock signal remains HIGH or LOW for a continuous
1-sec. period or more while the Ozone Fan Motor
remains energized.
C004E: Power Unit Cooling Fan
Motor malfunction
The Lock signal remains HIGH or LOW for a continuous
1-sec. period or more while the Power Unit Cooling
Fan Motor remains energized.
C0070: Main Hopper Toner
Replenishing Motor malfunction
• The Toner Bottle Home Position Sensor remains
blocked (L) for a continuous 2-sec. period or more
while the Main Hopper Toner Replenishing Motor
remains energized.
• The Toner Bottle Home Position Sensor remains
unblocked (H) for a continuous 6-sec. period or
more while the Main Hopper Toner Replenishing
Motor remains energized.
C0214: Abnormal image transfer
voltage
The image transfer voltage remains more than 100 V
for a continuous 0.1-sec. period or more while the PC
Drum remains stationary (except while an F2 operation
is being run).
C0500: Warming-up failure The temperature of the Fusing Rollers does not reach
the required level even after the lapse of a given
period of time during a warm-up cycle.
• From room temperature to 100 °C: Within 65 sec.
• From 100 °C to 140 °C: Within 30 sec.
• From 140 °C to 170 °C: Within 20 sec.
• From 170 °C to the completion of warming-up:
Within 22 sec.
C0510: Abnormally low fusing
temperature
• The fusing temperature remains 105 °C or less for a
continuous 0.1-sec. period or more during the
standby state or printing.
• The fusing temperature remains a level lower than
the following temperature for a continuous 2-min.
period or more during the low-temperature standby
state.
35-cpm copier: 105 °C
25-cpm copier: 80 °C
20-cpm copier (U.S.A. and Canada only): 80 °C
C0520 Abnormally high fusing
temperature
The fusing temperature remains 230 °C or more for a
continuous 0.1-sec. period or more.
C0650: Faulty Scanner Home
Position Sensor 1
or Start key pressed when the Scanner is at its
home position>
• The Scanner Home Position Sensor 1 is not
unblocked (H) even when the Scanner moves 10
mm to the left.
• The Scanner Home Position Sensor 1 is not blocked
(L) even when the Scanner moves 4 mm to the right
after the Scanner Home Position Sensor 1 has been
unblocked (H).
or Start key pressed when the Scanner is at any
position other than home>
• The Scanner Home Position Sensor 1 is not blocked
(L) even when the Scanner moves 469.5 mm to the right.
C0651: Faulty Scanner Home Position Sensor 2
When the Start key is pressed with a document loaded
in the Document Feed Tray of the ADF, Scanner Home
Position Sensor 2 is not blocked (L) even when the
Scanner moves 463 mm to the left after the sensor
has been unblocked (H).
C0990: LCC Lift-Up Motor failure to turn
See the relevant option service manual.
C0991: Lift 1 ascent motion failure
C0995: LCC Transport Motor failure to turn
C0999: Lift 2 ascent motion failure
C099D: LCC communication error
C0B00: Transport Motor drive malfunction
C0B20: Stapling Unit Moving Motor drive malfunction
C0B30: CD Aligning Motor drive malfunction
C0B38: Shift Motor drive malfunction
See the relevant option service manual.
C0B48: Exit Roller/Rolls Spacing
Motor drive malfunction
C0B4A: Storage Roller/Rolls
Spacing Motor drive malfunction
C0B4D Paper Holding Tray Motor
drive malfunction
C0B4E: Finisher Tray Motor drive
malfunction
C0B50: Stapling Motor 1 drive
malfunction / Stapling
Motor drive malfunction
C0B54: Stapling Motor 2 drive malfunction
C0B73: Punch Motor drive malfunction
C0B78: Hole Position Selector
Motor drive malfunction
(U.S.A. and Canada)
C0B80: Shift Motor drive malfunction
C0BA0: Elevator Motor drive malfunction
C0F32: Faulty ATDC Sensor The value of data read by the ATDC Sensor is faulty.
(ATDC Sensor reading is 19 % or more, or 7 % or less.)
C0F33: ATDC adjustment failure
• In an F8 (ATDC control voltage automatic adjustment)
operation, the adjustment of ATDC control
voltage is not completed within 1 min. after the
ATDC Sensor sampling.
• In an F8 operation, the control voltage falls outside
the range of 5.39 V to 8.15 V.
C1038: Engine connection error
• The system fails in checking initial engine connection
when the Power Switch is turned ON.
• The system succeeded in checking initial connection
when the Power Switch was turned ON; then it
fails in rechecking initial connection through the execution
of a software reset when a communications
error occurs during operation.
✽ For the printer controller malfunctions of “C18XX,” see Pi3502 service manual.
Code Description Detection Timing
C1300: Polygon Motor malfunction
• The Lock signal is not detected at any time during a
given period of time 1 sec. after the Polygon Motor
has been energized.
• No Lock signals are detected at any time during the
1-sec. period which starts 1 sec. after the first Lock.
• The Lock signal is not detected for a continuous 0.5-
sec. period while the Polygon Motor is in the stabilized
turning state.
• The Lock signal remains ON for a continuous 5-sec.
period while the Polygon Motor remains deenergized.
C133A: Communications error (G/A)
Communications with the gate array for expansion I/O
(the IC mounted on the Master Board) fail.
C133B: Communications error (option I/F)
The connection status of a finishing option is changed
after the power has been turned ON.
C13C0: I/C initialization failure After failing to blow the imaging cartridge fuse two
consecutive times, the I/C is determined to be new.
C13D0: Faulty EEPROM EEPROM, in which no initial data is written, is found.
C13F0: HSYNC detection failure • The SOS falling edge is not detected for 0.2 sec. or
more after the Polygon Motor has been energized
and laser output started.
• No SOS falling edges are detected while VIA
remains ON.
No hay comentarios: