Translate - Traductor

martes, 7 de julio de 2015

CODIGOS DE FALLA DI 350

C0000: Main Motor M2 malfunction
The Lock signal remains HIGH for a continuous 1-sec.
period or more while M2 remains energized.

C0010: I/C Motor M1 malfunction The Lock signal remains HIGH for a continuous 1-sec.
period or more while M1 remains energized.

C0045: Fusing Cooling Fan Motor M3 malfunction
The Lock signal remains HIGH or LOW for a continuous
1-sec. period or more while M3 remains energized.

C004C: Ozone Fan Motor M8 malfunction
The Lock signal remains HIGH or LOW for a continuous
1-sec. period or more while M8 remains energized.

C004E: Power Unit Cooling Fan Motor M4
The Lock signal (analog input voltage) remains 0.4V or
less for a continuous 0.5-sec. period or more while M4
remains energized.

C0070: Main Hopper Toner
Replenishing Motor M6 malfunction
· Toner Bottle Home Position Sensor PC10 remains
blocked (L) for a continuous 2-sec. period or more
while M6 remains energized.
· PC10 remains unblocked (H) for a continuous 6-sec.
period or more while M6 remains energized.

C0050: Warming-up failure The temperature of the Fusing Rollers do not reach the
required level even after the lapse of a given period of
time during a warming-up cycle.
· From room temperature to 100°C: Within 65 sec.
· From 100°C to 140°C: Within 25 sec.
· From 140°C to 170°C: Within 20 sec.
· From 170°C to the completion of warming-up: Within 22 sec.

C0510: Abnormally low fusing temperature
· The fusing temperature remains 130°C or less for a
continuous 0.1-sec. period or more during the
standby state or printing.
· The fusing temperature remains 105°C or less for a
continuous 2-min. period or more during the low-temperature
standby state.

C0520: Abnormally high fusing temperature
The fusing temperature remains 230°C or more for a
continuous 0.1-sec. period or more

C0650: Faulty Scanner Home Position Sensor 1 PC12
Start key pressed when the Scanner is at its home position>
· PC12 is not unblocked (H) even when the Scanner moves
10 mm to the left.
· PC12 is not blocked (L) even when the Scanner moves 4
mm to the right after PC12 has been unblocked (H).
Start key pressed when the Scanner is at any position other
than home>
· PC12 is not blocked (L) even when the Scanner moves
469.5 mm to the right.

C0651: Faulty Scanner Home Position Sensor 2 PC13
When the Start key is pressed with a document loaded in the
Document Feed Tray of AF-7, PC13 is not blocked (L) even
when the Scanner moves 463 mm to the left after PC12 has
been unblocked (H).

C0990: LCC Lift-Up Motor EMOT malfunction (PF-106)
] See option service manual.
C0991 Lift 1 ascent motion failure (PF-106)

C0995: LCC Transport Motor HMOT
malfunction (PF-106)
C0999 Lift 2 ascent motion failure (PF-106)

C099D: Communications error (PF-106)

C0B00: Transport Motor M1 drive malfunction
(FN-100/FN-500)

C0B0F: Paper Entrance Switching
Motor M1 drive malfunction
(FN-100/FN-500)

C0B30: CD Aligning Motor M4 drive
malfunction (FN-100/FN-500)

C0B38: Shift Motor M5 drive malfunction
(FN-100/FN-500)

C0B4D: Paper Holding Tray Motor M10
drive malfunction (FN-100/FN-500)

C0B4E: Finisher Tray Motor M8 drive
malfunction (FN-100/FN-500)

C0B50: Stapling Motor drive malfunction
(FN-100/FN-500)

C0BA0: Elevator Motor M9 drive malfunction
(FN-100/FN-500)

C0F32: Faulty ATDC Sensor E1 The value of data read by E1 is faulty. [E1 reading is 7% or
less (3.92V or more) or 19% or more (1.41V or less).]

C0F33: ATDC adjustment failure
· In an F8 (ATDC control voltage automatic adjustment)
operation, the adjustment of ATDC control voltage is not
completed within 1 min. after E1 sampling.
· In an F8 operation, the control voltage falls outside the
range of 5.39V to 8.15V.

C1038: Engine connection error
· The system fails in checking initial engine connection
when Power Switch S1 is turned ON.
· The system succeeded in checking initial connection
when S1 was turned ON; then it fails in rechecking
initial connection through the execution of a
software reset when a communications error occurs
during operation.

C1300: Polygon Motor M10 malfunction
· The Lock signal is not detected for a given period of
time after the resolution has been selected. (The
Lock signal is not, however, detected for 1 sec. after
the start.)
· No Lock signals are detected for the 1-sec. period
which starts 1 sec. after the first Lock.
] First Lock: The first Lock signal following 1 sec. after
the selection of start or half speed.
· The Lock signal is not detected for a continuous 0.5-
sec. period while M10 is in the stabilized turning
state (after a Lock has been detected).
· The Lock signal remains ON for a continuous 5-sec.
period while M10 remains deenergized.
C133A Communications error
(G/A)
———————————————————
C133B: Communications error
(option I/F)
———————————————————
C13C0: I/C initialization failure After failing to blow the imaging cartridge fuse 2 consecutive
times, 3.6V or more is detected and the I/C is
determined to be new.

C13D0: Faulty EEPROM No initial data is written in EEPROM.

C13F0: HSYNC detection failure · The SOS rising edge is not detected even after the
lapse of 0.2 sec. after Polygon Motor M10 has
started and laser output started.
· No SOS rising edges are detected while VIA
remains ON.

CODIGOS DE FALLA DI 250

MODO TECNICO
DI 250F Teclear: acceso, user number, 4 asteriscos (vuelve a la pantalla inicial), utility, mantenimiento, servece mode. Luego de usarlo, apagar y prender.

LISTA DE CODIGOS

C0000: Main Motor M2 malfunction
The Lock signal remains HIGH for a continuous 1-sec.
period or more while M2 remains energized.

C0010: I/C Motor M1 malfunction The Lock signal remains HIGH for a continuous 1-sec.
period or more while M1 remains energized.

C0045: Fusing Cooling Fan
Motor M3 malfunction
The Lock signal remains HIGH or LOW for a continuous
1-sec. period or more while M3 remains energized.

C004C:Ozone Fan Motor M8
malfunction
The Lock signal remains HIGH or LOW for a continuous
1-sec. period or more while M8 remains energized.

C004E: Power Unit Cooling Fan
Motor M4
The Lock signal (analog input voltage) remains 0.4V or
less for a continuous 0.5-sec. period or more while M4
remains energized.

C0070: Main Hopper Toner
Replenishing Motor M6 malfunction
· Toner Bottle Home Position Sensor PC10 remains
blocked (L) for a continuous 2-sec. period or more
while M6 remains energized.
· PC10 remains unblocked (H) for a continuous 6-sec.
period or more while M6 remains energized.

C0050: Warming-up failure The temperature of the Fusing Rollers do not reach the
required level even after the lapse of a given period of
time during a warming-up cycle.
· From room temperature to 100°C: Within 65 sec.
· From 100°C to 140°C: Within 25 sec.
· From 140°C to 170°C: Within 20 sec.
· From 170°C to the completion of warming-up: Within 22 sec.

C0510: Abnormally low fusing temperature
· The fusing temperature remains 130°C or less for a
continuous 0.1-sec. period or more during the
standby state or printing.
· The fusing temperature remains 80°C or less for a
continuous 2-min. period or more during the low-temperature
standby state.

C0520: Abnormally high fusing
temperature
The fusing temperature remains 230°C or more for a
continuous 0.1-sec. period or more.

C0650: Faulty Scanner Home Position
Sensor 1 PC12
Start key pressed when the Scanner is at its home position>
· PC12 is not unblocked (H) even when the Scanner moves
10 mm to the left.
· PC12 is not blocked (L) even when the Scanner moves 4
mm to the right after PC12 has been unblocked (H).
Start key pressed when the Scanner is at any position other
than home>
· PC12 is not blocked (L) even when the Scanner moves
469.5 mm to the right.

C0651: Faulty Scanner Home Position
Sensor 2 PC13
When the Start key is pressed with a document loaded in the
Document Feed Tray of AF-7, PC13 is not blocked (L) even
when the Scanner moves 463 mm to the left after PC12 has
been unblocked (H).

C0990: LCC Lift-Up Motor EMOT malfunction (PF-106)
] See option service manual.

C0991: Lift 1 ascent motion failure (PF-106)

C0995: LCC Transport Motor HMOT
malfunction (PF-106)

C0999: Lift 2 ascent motion failure (PF-106)

C099D: Communications error (PF-106)

C0B00: Transport Motor M1 drive malfunction
(FN-100/FN-500)

C0B0F: Paper Entrance Switching
Motor M1 drive malfunction
(FN-100/FN-500)

C0B30: CD Aligning Motor M4 drive
malfunction (FN-100/FN-500)

C0B38: Shift Motor M5 drive malfunction
(FN-100/FN-500)

C0B4D: Paper Holding Tray Motor M10
drive malfunction (FN-100/FN-500)

C0B4E: Finisher Tray Motor M8 drive
malfunction (FN-100/FN-500)

C0B50: Stapling Motor drive malfunction
(FN-100/FN-500)

C0BA0: Elevator Motor M9 drive malfunction
(FN-100/FN-500)

C0F32: Faulty ATDC Sensor E1 The value of data read by E1 is faulty. [E1 reading is 7% or
less (3.92V or more) or 19% or more (1.41V or less).]

C0F33: ATDC adjustment failure · In an F8 (ATDC control voltage automatic adjustment)
operation, the adjustment of ATDC control voltage is not
completed within 1 min. after E1 sampling.
· In an F8 operation, the control voltage falls outside the
range of 5.39V to 8.15V.

C1038: Engine connection error · The system fails in checking initial engine connection
when Power Switch S1 is turned ON.
· The system succeeded in checking initial connection
when S1 was turned ON; then it fails in rechecking
initial connection through the execution of a
software reset when a communications error occurs
during operation.

C1300: Polygon Motor M10 malfunction
· The Lock signal is not detected for a given period of
time after the resolution has been selected. (The
Lock signal is not, however, detected for 1 sec. after
the start.)
· No Lock signals are detected for the 1-sec. period
which starts 1 sec. after the first Lock.
] First Lock: The first Lock signal following 1 sec. after
the selection of start or half speed.
· The Lock signal is not detected for a continuous 0.5-
sec. period while M10 is in the stabilized turning
state (after a Lock has been detected).
· The Lock signal remains ON for a continuous 5-sec.
period while M10 remains deenergized.
C133A: Communications error (G/A)
———————————————————
C133B: Communications error
(option I/F)
———————————————————
C13C0: I/C initialization failure After failing to blow the imaging cartridge fuse 2 consecutive
times, 3.6V or more is detected and the I/C is
determined to be new.

C13D0: Faulty EEPROM No initial data is written in EEPROM.

C13F0: HSYNC detection failure · The SOS rising edge is not detected even after the
lapse of 0.2 sec. after Polygon Motor M10 has
started and laser output started.
· No SOS rising edges are detected while VIA
remains ON.

CODIGOS DE FALLA DI 200, 251, 351

MODO TECNICO

LISTA DE CODIGOS

C0000: Main Motor malfunction The Lock signal remains HIGH for a continuous 1-sec.
period while the Main Motor remains energized.

C0010: I/C Motor malfunction The Lock signal remains HIGH for a continuous 1-sec.
period while the I/C Motor remains energized.

C0045: Cooling Fan Motor malfunction
The Lock signal remains HIGH or LOW for a continuous
1-sec. period or more while the Cooling Fan Motor
remains energized.

C004C: Ozone Fan Motor malfunction
The Lock signal remains HIGH or LOW for a continuous
1-sec. period or more while the Ozone Fan Motor
remains energized.

C004E: Power Unit Cooling Fan
Motor malfunction
The Lock signal remains HIGH or LOW for a continuous
1-sec. period or more while the Power Unit Cooling
Fan Motor remains energized.

C0070: Main Hopper Toner
Replenishing Motor malfunction
• The Toner Bottle Home Position Sensor remains
blocked (L) for a continuous 2-sec. period or more
while the Main Hopper Toner Replenishing Motor
remains energized.
• The Toner Bottle Home Position Sensor remains
unblocked (H) for a continuous 6-sec. period or
more while the Main Hopper Toner Replenishing
Motor remains energized.

C0214: Abnormal image transfer
voltage
The image transfer voltage remains more than 100 V
for a continuous 0.1-sec. period or more while the PC
Drum remains stationary (except while an F2 operation
is being run).

C0500: Warming-up failure The temperature of the Fusing Rollers does not reach
the required level even after the lapse of a given
period of time during a warm-up cycle.
• From room temperature to 100 °C: Within 65 sec.
• From 100 °C to 140 °C: Within 30 sec.
• From 140 °C to 170 °C: Within 20 sec.
• From 170 °C to the completion of warming-up:
Within 22 sec.

C0510: Abnormally low fusing
temperature
• The fusing temperature remains 105 °C or less for a
continuous 0.1-sec. period or more during the
standby state or printing.
• The fusing temperature remains a level lower than
the following temperature for a continuous 2-min.
period or more during the low-temperature standby
state.
35-cpm copier: 105 °C
25-cpm copier: 80 °C
20-cpm copier (U.S.A. and Canada only): 80 °C
C0520 Abnormally high fusing
temperature
The fusing temperature remains 230 °C or more for a
continuous 0.1-sec. period or more.

C0650: Faulty Scanner Home
Position Sensor 1
or Start key pressed when the Scanner is at its
home position>
• The Scanner Home Position Sensor 1 is not
unblocked (H) even when the Scanner moves 10
mm to the left.
• The Scanner Home Position Sensor 1 is not blocked
(L) even when the Scanner moves 4 mm to the right
after the Scanner Home Position Sensor 1 has been
unblocked (H).
or Start key pressed when the Scanner is at any
position other than home>
• The Scanner Home Position Sensor 1 is not blocked
(L) even when the Scanner moves 469.5 mm to the right.

C0651: Faulty Scanner Home Position Sensor 2
When the Start key is pressed with a document loaded
in the Document Feed Tray of the ADF, Scanner Home
Position Sensor 2 is not blocked (L) even when the
Scanner moves 463 mm to the left after the sensor
has been unblocked (H).

C0990: LCC Lift-Up Motor failure to turn
See the relevant option service manual.

C0991: Lift 1 ascent motion failure

C0995: LCC Transport Motor failure to turn

C0999: Lift 2 ascent motion failure

C099D: LCC communication error

C0B00: Transport Motor drive malfunction

C0B20: Stapling Unit Moving Motor drive malfunction

C0B30: CD Aligning Motor drive malfunction

C0B38: Shift Motor drive malfunction
See the relevant option service manual.

C0B48: Exit Roller/Rolls Spacing
Motor drive malfunction

C0B4A: Storage Roller/Rolls
Spacing Motor drive malfunction
C0B4D Paper Holding Tray Motor
drive malfunction

C0B4E: Finisher Tray Motor drive
malfunction

C0B50: Stapling Motor 1 drive
malfunction / Stapling
Motor drive malfunction

C0B54: Stapling Motor 2 drive malfunction

C0B73: Punch Motor drive malfunction

C0B78: Hole Position Selector 
Motor drive malfunction
(U.S.A. and Canada)

C0B80: Shift Motor drive malfunction

C0BA0: Elevator Motor drive malfunction

C0F32: Faulty ATDC Sensor The value of data read by the ATDC Sensor is faulty.
(ATDC Sensor reading is 19 % or more, or 7 % or less.)

C0F33: ATDC adjustment failure 
• In an F8 (ATDC control voltage automatic adjustment)
operation, the adjustment of ATDC control
voltage is not completed within 1 min. after the
ATDC Sensor sampling.
• In an F8 operation, the control voltage falls outside
the range of 5.39 V to 8.15 V.

C1038: Engine connection error 
• The system fails in checking initial engine connection
when the Power Switch is turned ON.
• The system succeeded in checking initial connection
when the Power Switch was turned ON; then it
fails in rechecking initial connection through the execution
of a software reset when a communications
error occurs during operation.

✽ For the printer controller malfunctions of “C18XX,” see Pi3502 service manual.
Code Description Detection Timing

C1300: Polygon Motor malfunction
• The Lock signal is not detected at any time during a
given period of time 1 sec. after the Polygon Motor
has been energized.
• No Lock signals are detected at any time during the
1-sec. period which starts 1 sec. after the first Lock.
• The Lock signal is not detected for a continuous 0.5-
sec. period while the Polygon Motor is in the stabilized
turning state.
• The Lock signal remains ON for a continuous 5-sec.
period while the Polygon Motor remains deenergized.

C133A: Communications error (G/A)
Communications with the gate array for expansion I/O
(the IC mounted on the Master Board) fail.

C133B: Communications error (option I/F)
The connection status of a finishing option is changed
after the power has been turned ON.

C13C0: I/C initialization failure After failing to blow the imaging cartridge fuse two
consecutive times, the I/C is determined to be new.

C13D0: Faulty EEPROM EEPROM, in which no initial data is written, is found.

C13F0: HSYNC detection failure • The SOS falling edge is not detected for 0.2 sec. or
more after the Polygon Motor has been energized
and laser output started.
• No SOS falling edges are detected while VIA
remains ON.