Translate - Traductor

martes, 18 de agosto de 2015

CODIGOS DE FALLA BIZHUB 162, 211, 220


LISTA DE CODIGOS

C0000: Main motor malfunction
• The main motor (M1) lock signal remains HIGH for a continuous
1-sec. period at any time 1 sec. after the main
motor has started turning.

C0044 ADF cooling fan failure
(Only when the optional
DF-605 is mounted)
.
C0045 Fusing cooling fan motor
malfunction
• The fusing cooling fan motor (FM1) lock signal remains
HIGH for a continuous 1-sec. period while the fusing cooling
fan motor is turning at full speed or decelerated speed.

C004E Power supply cooling fan
motor malfunction
• The power supply cooling fan motor (FM2) lock signal
remains HIGH for a continuous 1-sec. period while the
power supply cooling fan motor remote signal remains ON
(for full-speed rotation) or OFF (for decelerated-speed rotation).

C0070 Toner replenishing motor
malfunction
• The toner bottle home position sensor (PS6) outputs a
HIGH signal for a continuous 3.5-sec. period while the
toner bottle is turning.
• The toner bottle home position sensor (PS6) outputs a
LOW signal for a continuous 2-sec. period while the toner
bottle is turning.

C0210 Abnormal image transfer
voltage
• The image transfer voltage remains more than 100 V continuously
for a given period of time while the PC drum
remains stationary.

C03FF Faulty model setting
• “Model Setting” of “Adjust” available from the Service mode
is incorrectly set.

C0500 Warm-up failure
• The surface temperature of the fusing roller does not reach
a given level even after the lapse of a given period of time
during a warm-up cycle. 
Warm-up failure
(for the model having two
fusing roller heater lamps)
*bizhub 211/220 only
• The thermistor (TH1) does not detect a predetermined
temperature within 30 sec. after a warm-up cycle has been
started and thus the warm-up cycle is not completed.
• The surface temperature of the fusing roller does not reach
a given level even after the lapse of a given period of time
during a warm-up cycle.

C0501 Warm-up failure 2
(for the model having two
fusing roller heater lamps)
*bizhub 211/220 only
• The sub thermistor (TH2) does not detect a predetermined
temperature within 30 sec. after a warm-up cycle has been
started and thus the warm-up cycle is not completed.
• The surface temperature of the fusing roller does not reach
a given level even after the lapse of a given period of time
during a warm-up cycle.

C0510 Fusing failure
(abnormally low fusing
temperature)
• The temperature detected by the thermistor (TH1) remains
lower than 120°C (105°C for the model having two fusing
roller heater lamps) for a given period of time during the
standby state.
• The temperature detected by the thermistor (TH1) remains
lower than 120°C (105°C for the model having two fusing
roller heater lamps) for a given period of time during a print cycle.

C0511 Fusing failure
(abnormally low fusing
temperature 2)
*bizhub 211/220 only
• The temperature detected by the sub thermistor (TH2)
remains lower than 105°C for a given period of time during
the standby state.
• The temperature detected by the sub thermistor (TH2)
remains lower than 105°C for a given period of time during
a print cycle.

C0520 Fusing failure
(abnormally high fusing
temperature)
• The temperature detected by the thermistor (TH1) remains
higher than 240°C for a given period of time.

C0521 Fusing failure
(abnormally high fusing
temperature 2)
*bizhub 211/220 only
• The temperature detected by the sub thermistor (TH2)
remains higher than 240°C for a given period of time.

C0650 Faulty scanner home
position sensor
• The scanner home position sensor (PS100) does not go
from HIGH to LOW when the scanner motor (M4) is energized
for a given number of steps after the sequence to
bring the scanner back to its home position has been
started at the end of a scan motion and during re-shading.
• The scanner home position sensor (PS100) does not go
from LOW to HIGH when the scanner motor (M4) is energized
for a given number of steps after a scan motion has
been started at the end of a PS100 home check scan
motion and during re-shading.

C0B60 Bin switching motor malfunction
(Only when the optional
JS-503 is mounted)

C0B80 Shift motor malfunction
(Only when the optional
SF-501 is mounted)

C0F32 Faulty TCR sensor
• The measurement taken by the TCR sensor (TSRS) at a
time 2.0 sec. after the main motor (M1) has started turning
is less than 5% (greater than 4.63 V).
• The measurement taken by the TCR sensor (TCRS) at a
time 2.0 sec. after the main motor (M1) has started turning
is 19% or more (1.41 V or less).

C0F33 Improperly adjusted TCR sensor
• The adjustment of the TCR control voltage is not completed
within 1 sec. after sampling has started of the TCR
sensor (TCRS) as part of an operation of TCRS sensor
automatic adjustment.
• The TCR sensor control voltage falls outside the range of
5.39 V to 8.15 V during an operation of TCR sensor automatic
adjustment.

C1038 Engine connection failure
Printer control board (PRCB) to MFP board (MFPB) connection
failure
• There is no acknowledge signal transmitted from the
printer control board (PRCB) to MFP board (MFPB) for 1.5
sec. or more.
• An error command signal is transmitted from the MFP
board (MFPB) to printer control board (PRCB).
• An error status signal is transmitted from the printer control
board (PRCB) to MFP board (MFPB).

C1200 Faulty ASIC/memory
ASIC/memory (for image and control) fault
• A write or read error occurs with SRAM on the MFP board
(MFPB).

C1300 Polygon motor
malfunction
Startup failure
• A LOW polygon motor lock signal is not detected within a
given period of time that begins 1 sec. after the polygon
motor has started turning.
Lock signal fault: Unstable after the first lock signal has been
detected
• For a period of 1 sec. after the first LOW polygon motor
lock signal (first Lock) has been detected, the next LOW
polygon motor lock signal is not detected.
Lock signal fault: Lock signal out-of-timing
• A LOW polygon motor lock signal is not detected for a continuous
given period of time while the rotation of the polygon
motor remains stabilized.
Faulty lock signal
• A LOW polygon motor lock signal is detected for a given
period of time or more when the polygon motor remains
deenergized.

C133B Communication with
option error See P.117 of the FK-506 service manual.

C133D ROM check error

C13F0 Faulty HSYNC
Laser scanning system malfunction
• The SOS sensor does not detect a rising edge of SOS
within a given period of time after the polygon motor has
started turning and a laser output has been started.
• The SOS sensor detects no rising edges of SOS while VIA
(image area control) is ON.
Code Item Description

C1468 Faulty parameter chip
• Contact the responsible people of KMBT before taking
some countermeasures.

C14A3 IR fluorescent lamp fault
The exposure lamp (LA1) of the scanner fails to turn ON.
• The intensity of the exposure lamp is a predetermined
value or less during shading and re-shading.

C3FFF Flash ROM error
• The copier determines that there is an error if writing to the
flash ROM fails during upgrading of the firmware.
• When the power switch is turned ON, the error indicator
lights up steadily and a corresponding message appears
on the display.
• If this error message appears, no operations can then be
performed. It is not possible to upgrade the firmware from a

PC connected through USB connection, either.

No hay comentarios: